Follow

Hazardous Location Certification

Question:  What certifications do the wireless sensors have for hazardous location?

 

Answer: 

The Accel 310 wireless sensors are certified for ATEX / IECx and North American UL/CSA as outlined below:

  • Product name: Treon Industrial Node 6 Ex
  • Unique Identifier: Treon Industrial Node, model 2111, variant 6k Ex

 

EU DECLARATION OF CONFORMITY

See the source image

Hereby, Treon Oy declares that the radio equipment Treon Industrial Node
is in compliance with Directive 2014/53/EU.
https://www.treon.fi/documentation/

 

ATEX/IECEx

See the source image

EESF 21 ATEX 014X
IECEx EESF 21.0009X
II 2 G Ex ib IIC T4 Gb
II 2 D Ex ib IIIC T135°C Db
-40°C ≤ Ta ≤ +60°C

 

North America

mceclip0.png

UL61010-1/CSA C22.2 No. 61010-1
UL/CSA 60950-22
UL 60079
CSA 60079
E115489

USA
Class I Zone 1 AEx ib IIC T4 Gb
Zone 21 AEx ib IIIC T135°C Db
Class I, Division 2, Groups A,B,C,D T4
Class II, Division 2, Groups F,G T4
Class III, Division 2
-40°C ≤ Ta ≤ +60°C
Canada
Ex ib IIC T4 Gb
Ex ib IIIC T135°C Db
-40°C ≤ Ta ≤ +60°C

 